数据库 发布日期:2024/12/26 浏览次数:1
前言
有网友指出,SQL Server 2012中fn_PhysLocFormatter内部函数在解析数据行记录位置时存在错误,见:http://www.itpub.net/thread-1751655-1-1.html,实际测试后发现,一是2008R2中同样存在问题,二是不仅页号解析存在问题,槽号解析也存在同样问题。
下面先查看表NT_SiteInfo的数据行记录位置。
select SiteID,%%physloc%%,sys.fn_PhysLocFormatter(%%physloc%%) from NT_SiteInfo
SiteID
%%physloc%%
sys.fn_PhysLocFormatter(%%physloc%%)
1
0xE900000001000000
(1:59648:0)
23
0xE900000001000100
(1:59648:1)
24
0xE900000001000200
(1:59648:2)
......
149
0xE900000001007F00
(1:59648:127)
150
0xE900000001008000
(1:59648:128)
151
0xE900000001008100
(1:59648:33024)
152
0xE900000001008200
(1:59648:33280)
......
226
0xE90000000100CC00
(1:59648:52224)
227
0xE90000000100CD00
(1:59648:52480)
228
0x4B02000001000000
(1:587:0)
229
0x4B02000001000100
(1:587:1)
......
360
0x4B02000001007F00
(1:587:127)
361
0x4B02000001008000
(1:587:128)
362
0x4B02000001008100
(1:587:33024)
363
0x4B02000001008200
(1:587:33280)
......
422
0x4B0200000100BD00
(1:587:48384)
423
0x4B0200000100BE00
(1:587:48640)
424
0x3C05000001000000
(1:1340:0)
425
0x3C05000001000100
(1:1340:1)
......
552
0x3C05000001008000
(1:1340:128)
553
0x3C05000001008100
(1:1340:33024)
596
0x3C0500000100AC00
(1:1340:44032)
597
0x9978000001000000
(1:39288:0)
......
658
0x9978000001003D00
(1:39288:61)
下面查看表NT_SiteInfo分配的数据页情况。
dbcc ind(wjgk,nt_siteinfo,0)
PagePID
IAMFID
IAMPID
PageType
IndexLevel
NextPagePID
PrevPagePID
238
NULL
NULL
10
NULL
0
0
233
1
238
1
0
587
0
587
1
238
1
0
1340
233
1340
1
238
1
0
30873
587
30873
1
238
1
0
0
1340
Microsoft未公开的伪列%%physloc%%,类型为Binary(8),返回表中记录的RowID,格式是:前4字节表示页号,中间2字节表示文件号,最后2字节表示槽号。
对照上面的实际数据,可以发现sys.fn_PhysLocFormatter
在解析记录位置时,既有采用高字节在前的BIG_ENDIAN格式,又有采用低字节在前的LITTLE_ENDIAN格式,造成采用高字节在前的BIG_ENDIAN格式解析的数据错误:
页号解析:
E9000000解析为59648(E900),错误,实际应为233(E9)
4B020000解析为576(24B),正确
3C050000解析为1340(53C),正确
99780000解析为39288(9978),错误,实际应为30873(7899)
槽号解析:
8000解析为128(0080),正确
8100解析为33024(8100),错误,应为129(0081)
下面给出错误原因。
先看下sys.fn_PhysLocFormatter
函数的定义:
select OBJECT_DEFINITION(object_id('sys.fn_PhysLocFormatter')) go ------------------------------------------------------------------------------- -- Name: sys.fn_PhysLocFormatter -- -- Description: -- Formats the output of %%physloc%% virtual column -- -- Notes: ------------------------------------------------------------------------------- create function sys.fn_PhysLocFormatter (@physical_locator binary (8)) returns varchar (128) as begin declare @page_id binary (4) declare @file_id binary (2) declare @slot_id binary (2) -- Page ID is the first four bytes, then 2 bytes of page ID, then 2 bytes of slot -- select @page_id = convert (binary (4), reverse (substring (@physical_locator, 1, 4))) select @file_id = convert (binary (2), reverse (substring (@physical_locator, 5, 2))) select @slot_id = convert (binary (2), reverse (substring (@physical_locator, 7, 2))) return '(' + cast (cast (@file_id as int) as varchar) + ':' + cast (cast (@page_id as int) as varchar) + ':' + cast (cast (@slot_id as int) as varchar) + ')' end
再看下reverse函数:
select reverse('工人') ---- 人工 (1 行受影响) select reverse('12345工人') --------- 人工54321 (1 行受影响) select reverse('工12345人') --------- 人54321工 (1 行受影响)
结论:问题出在reverse函数上。
reverse函数的作用是字符反转,而不是字节反转,当遇到81-FE之间的字节时,被认为是双字节字符而组合在一起参与反转操作,造成了错误。
总结
以上就是这篇文章的全部内容了,希望本文的内容对大家的学习或者工作能带来一定的帮助,如果有疑问大家可以留言交流,谢谢大家对的支持。